Notifications
You must be signed in to change notification settings - Fork 0
/
load_prefilter_scan.pro
108 lines (93 loc) · 4.52 KB
/
load_prefilter_scan.pro
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
;-------------------------------------------------------------
;+
; NAME:
; load_prefilter_scan
; PURPOSE:
;
; CATEGORY:
; CALLING SEQUENCE:
; prefilter_scan = load_profile_scan (prefilter_scan_location)
; INPUTS:
; prefilter_scan_location = structure as output by parse_prefilter_scan_log.pro
; KEYWORD PARAMETERS:
; verbose = turns on prining of each log line for the requested prefilter scan
; OUTPUTS:
; prefilter_scan = structure containing information on the selected prefilter scan
; see details on structure contents in NOTES section.
; COMMON BLOCKS:
;
; NOTES:
; The input to this function is a single element of the structure returned by
; the parse_prefilter_scan_log.pro program.
;
; e.g. IDL> prefilter_log_scans = parse_prefilter_scan_log (filter_name)
; IDL> prefilter_scan = load_profile_scan (prefilter_log_scans(i))
;
; IDL> HELP, prefilter_scan, /STRUCTURE
; ** Structure <7078e0>, 10 tags, length=1544, data length=1544, refs=1:
; COUNTS - the measured intensity at each given Fabry-Perot tuning
; WAVELENGTHS - the wavelengths (relative to the determined peak of given filter)
; corresponding to each measured intensity
; FP1_VOLTAGES - the voltage applied to Fabry-Perot #1 for each given measurement
; FP2_VOLTAGES - the voltage applied to Fabry-Perot #2 for each given measurement
; SCAN_LOCATION - starting position (from POINT_LUN) for prefilter scan
; SCAN_START_DATE - starting date of prefilter scan as a Julian date
; SCAN_END_DATE - ending date of prefilter scan as a Julian date
; SCAN_DATE_TEXT - the starting and ending dates given in original format
; LOGFILE_USED - name of the log file to which the parsing
; FILTER_NAME - input name of filter
;
; Scan lengths or wavelength coverage may vary between scans, even those located in
; the same log file, and this program does nothing to normalize these differences.
;
; MODIFICATION HISTORY:
; 19 Jul, 2003 - KPR - added documentation
; 26 Apr, 2015 - KPR - added additional documentation
;
;-
;-------------------------------------------------------------
FUNCTION load_prefilter_scan, prefilter_scan_location, verbose=verbose
IF N_ELEMENTS(verbose) LT 1 THEN verbose=0
scan_start = 'Begin Prefilter Scan'
scan_end = 'End Prefilter Scan'
measurement_line = 'Continuum Lamp'
input_record = ''
current_line = -1L
prefilter_counts = 0.
wavelengths = 0.
fp1_voltages = 0.
fp2_voltages = 0.
logfile = prefilter_scan_location.scan_log_file
scan_location = prefilter_scan_location.scan_start_position
GET_LUN,log_lun
OPENR,log_lun,logfile
POINT_LUN, log_lun, scan_location
WHILE NOT (EOF(log_lun)) AND NOT (STRMATCH(input_record, scan_end + '*', /FOLD_CASE)) DO BEGIN
READF,log_lun,input_record
current_line = current_line + 1
IF STRMATCH(input_record, measurement_line + '*', /FOLD_CASE) THEN BEGIN
input_fields = STRSPLIT(input_record, /EXTRACT)
v2start = STRPOS(input_fields(9),'=')
v2end = STRPOS(input_fields(9),')')
v2 = STRMID(input_fields(9), v2start+1, v2end-v2start-1)
prefilter_counts = [prefilter_counts, input_fields(2)]
wavelengths = [wavelengths, input_fields(5)]
fp1_voltages = [fp1_voltages, input_fields(8)]
fp2_voltages = [fp2_voltages, v2]
ENDIF ELSE BEGIN
IF verbose GE 1 THEN PRINT,input_record
ENDELSE
ENDWHILE
FREE_LUN, log_lun
prefilter_scan = CREATE_STRUCT('counts' , prefilter_counts(1:*), $
'wavelengths' , wavelengths(1:*), $
'fp1_voltages' , fp1_voltages(1:*), $
'fp2_voltages' , fp2_voltages(1:*), $
'scan_location' , scan_location, $
'scan_start_date' , prefilter_scan_location.scan_start_date, $
'scan_end_date' , prefilter_scan_location.scan_end_date, $
'scan_date_text' , prefilter_scan_location.scan_date_text, $
'logfile_used' , logfile, $
'filter_name' , prefilter_scan_location.filter_name)
RETURN, prefilter_scan
END ; load_prefilter_scan