Nanoseconds vs ticks. #131

Closed
VentuzVictorPerez opened this issue Apr 26, 2021 · 6 comments
Closed

Nanoseconds vs ticks. #131

VentuzVictorPerez opened this issue Apr 26, 2021 · 6 comments

Comments

@VentuzVictorPerez
Copy link

Hello.

I am implementing the IS-05 in .NET (C#), here the smallest unit of time is the tick (which is equal to 100 nanoseconds).

It is clear to me that in NMOS the base unit is the nanoseconds since this is how the versions and activations ("activate_scheduled_absolute" and "activate_scheduled_relative") are based.

What can I do in this case? Is it mandatory to have a base unit of nanoseconds?

Thanks in advance.

Victor.

@garethsb
Copy link
Contributor

Flippant answer: multiply by 100

Yes, the base unit for TAI timestamps is always nanoseconds.

If you can't actually schedule activations to the requested precision, and instead schedule at the nearest 100ns, nearest video frame (or nearest second!), that's a QoI issue but valid per the spec. There is however no way to indicate the (lack of) precision to the client, and there's a related issue, #107.

@garethsb garethsb transferred this issue from AMWA-TV/is-04 Apr 26, 2021
@VentuzVictorPerez
Copy link
Author

Cool, Thanks!

@VentuzVictorPerez
Copy link
Author

VentuzVictorPerez commented May 12, 2021

Hello.

Back on topic.

What exactly do you mean by "QoI issue"? What is "Qol"?

About the scheduled activations:

The time stamp given in "requested_time" is based on nanoseconds.

Does the specification then require nanosecond precision to perform the activation? Or what exactly does the specification say? I can't find it.

I know that there is already an issue about it (you mentioned it above) I just want to know what the specification says.

Thanks in advance.

Victor

@garethsb
Copy link
Contributor

The accuracy of the activation is, as far as I'm aware, not covered by the spec, it's left as a Quality of Implementation issue.

@peterbrightwell
Copy link
Contributor

Is any clarification needed in the spec before we close this and publish v1.1.1?

@peterbrightwell
Copy link
Contributor

I am going to say not (#107 is tagged enhancement) and closing.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment